| Specification |
After-sales Service: Life Long Support;
Warranty: 1 Year or Extend;
Type: Cable Fault Locator;
Display: LCD;
Control: Manual Control;
Weight: 12kgs;
Power Source: AC220V;
Testing Method: Low Pressure Pulse Method, Impulse Lightning Flow;
Frequency: 6.25MHz,12.5MHz,25MHz,50MHz,100MHz;
Output Voltage: 0~-35kv;
Discharge Engergy: ≤1225j(2450j);
Component 1: Tdr Host;
Component 2: Hv Power Supply;
Component 3: Path Locator and Pinpointing Meter;
Component 4: Arc Generator (Option);
Test Distance: Max up to 100km;
Lead Time: 10 Working Days;
Product Name: Cable Fault Locator;
Model Type: Hm-A10;
Standard: IEC;
Power Supply: 220V;
|
After-sales Service: Suppor for Lifelong;
Warranty: 12months or Extended;
Type: Transformer Oil Tester;
Titration Method: Coulometric Titration (Coulomb Analysis);
Power: < 40W;
Ambient Humidity: <=85%;
Standard: IEC;
Flash Fire Sensor: Thermocouple;
Frequency: 50Hz±10%;
Input Power: AC220V±20%;
Accuracy: 0.5%;
Repeatability: 0.5%;
Product Name: Oil Closed Cup Flash Point Test Set;
Model Type: Hm501;
Indoor Temperature Range: up to 400 Degree Centigrade;
Gross Weight: 25kgs;
Measuring Size: 440*560*530mm;
|
After-sales Service: Suppor for Lifelong;
Warranty: 12months or Extended;
Type: Transformer Oil Tester;
Titration Method: Coulometric Titration (Coulomb Analysis);
Power: < 40W;
Ambient Humidity: <=85%;
Standard: IEC;
Flash Fire Sensor: Thermocouple;
Frequency: 50Hz±10%;
Input Power: AC220V±20%;
Accuracy: 0.5%;
Repeatability: 0.5%;
Product Name: Oil Closed Cup Flash Point Test Set;
Model Type: Hm501;
Indoor Temperature Range: up to 400 Degree Centigrade;
Gross Weight: 25kgs;
Measuring Size: 440*560*530mm;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300Ω;Accuracy:2%±2mΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC,Iee;
Model Name: CT PT Analyzer;
Model Type: Hmcop-100p;
Application: Test for Protection Class CT, Protection Class PT;
Power Supply: AC220V;
PT Ratio Accuracy: ±0.2%;
|
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: CT/PT Analyzer;
Accuracy Grade: 0.2%;
Load Way: Electronic Load;
Loading Method: Dynamic Load;
Display: Digital;
Control: Computer Control;
Weight: <9kg;
Power Source: AC220V;
Usage: Class P/Tp CT & Vt;
Output: 0~100vrms,12arms,36A(Peak Value);
Voltage Measurement Accuracy: ±0.2%;
CT Ratio: Range:1~30000;Accuracy:±0.2%;
PT Ratio: Range:1~10000;Accuracy:±0.2%;
Phase: Range:±5min;Accuracy:0.5min;
DC Resistance: Range:0~300Ω;Accuracy:2%±2mΩ;
Burden: Range:0~300va;Accuracy:2%±0.2va;
Standard: IEC,Iee;
Model Name: CT PT Analyzer;
Model Type: Hmcop-100p;
Application: Test for Protection Class CT, Protection Class PT;
Power Supply: AC220V;
PT Ratio Accuracy: ±0.2%;
|