| Specification |
Type: Hall Type;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: ±2 % of Ipn;
Application: New Energy EV Charging Pile;
Customized: Customized;
Supply Voltage: 5V;
Product: Current Sensor;
Primary Nominal RMS Current: 50A 100A 150A 200A 250A 300A;
|
Type: Electromagnetic;
Output Signal Type: Analog Output;
Production Process: SemiConductor Integrated;
Material: Plastic;
Accuracy Grade: 0.5G;
Application: Hard-Switching;
IP Rating: IP20;
Customized: Customized;
Usage: Current;
Phase: Three;
Coil Structure: Ring;
Rated Frequency: 50Hz/60Hz;
|
Type: Electromagnetic;
Output Signal Type: Digital Output;
Production Process: SemiConductor Integrated;
Material: Stainless Steel;
Accuracy Grade: 1.0G;
Application: Power, Electronic;
IP Rating: IP20;
Customized: Customized;
Phase: Single;
Coil: Core-Type Transformer;
|
Type: Integrator;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Rated Output: 5V AC RMS,4V DC(True-RMS),4-20mA;
Output Ripple Factor: 0.5%;
Response Time: ≤1us;
Power Consumption: 150MW;
Bandwidth: 10Hz to 20kHz;
Rated Input: 100A-6000A;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Output on 0A (Zero Drift): ≤2mv;
Temperature Drift: 200ppm/℃;
Power Supply: 12V or 24V(Best Performance on 24V Default);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Y-Fct, Nrc, Mrc, Zrc;
Installation Field Site: Industrial Integrator in Distribution Box;
|
Type: Integrator;
Output Signal Type: Analog Output;
Production Process: Integration;
Material: Plastic;
Accuracy Grade: 0.5% Typical at 1%(≥10A) to 200% of Rated;
Application: Integrate,Amplify,Convert Electric Signals;
IP Rating: IP20;
Customized: Customized;
Rated Output: 5V AC RMS,4V DC(True-RMS),4-20mA;
Output Ripple Factor: 0.5%;
Response Time: ≤1us;
Power Consumption: 150MW;
Bandwidth: 10Hz to 20kHz;
Rated Input: 100A-6000A;
Phase Error: ≤0.5°;
Linearity: ±0.2% of Reading(1% to 200% of Range);
Minimum Current Measurement: 1A (Ripple 100mA);
Output on 0A (Zero Drift): ≤2mv;
Temperature Drift: 200ppm/℃;
Power Supply: 12V or 24V(Best Performance on 24V Default);
Operating Temperature: -20℃ to 70℃;
Current Sensor: Y-Fct, Nrc, Mrc, Zrc;
Installation Field Site: Industrial Integrator in Distribution Box;
|