| Specification |
After-sales Service: Response on Customers' Questions Within 12 Hours.;
Warranty: 12 Months;
Description: Automatic Z Type Transformer Turns Ratio Test Set;
Functions: Test Parameters of Z Type Transformer;
Application Field: Electrical Industry, Transformer Manufacturer;
Features: Automatic Z Type Transformer Turns Ratio Test Set;
Reference Standards: IEC76-1 and IEC60044;
Ratio Measurement Range: 1-10000;
Group Measurement: 1-12;
Max. Test Timestest Voltage: AC 0~80V Continuously, Frequency 50Hz;
Dimension: 400mm*350mm*200 mm;
Weight: 8kg;
Power Supply: AC 220V, 50Hz/60Hz;
Delivery Lead Time: 7 Days After The Order Is Confirmed;
Shipping Method: Suggest to Ship by Air or Express;
Trade Terms: EXW, Fob, DDU, Cit, etc.;
Payment Term: 30% as Deposit, The Balance Before Delivery;
|
After-sales Service: Yes;
Warranty: 1 Year;
Input Voltage: AC 220 V;
Test Voltage Control Error: ≤ 2%;
Dimension: 100*50*120(Cm);
Customized Support: OEM, ODM;
Test Mode: Intermittent Arc, Continuous Arc;
Output Voltage: AC 0--20 Kv;
Test Voltage Continuously Adjustable: 0--20 Kv;
Test Current: 10mA-20mA-30mA-40mA Optional;
Power: Electronic;
Electrical Capacity: 1.5 kVA;
Arc on-off Time Error: <5ms;
|
After-sales Service: Yes;
Warranty: 1 Year;
Relative Humidity: ≤ 85%;
Experimental Voltage: AC100 ± 10V;
Timing Device: 0-9 Minutes and 59 Seconds;
Timing Error: ± 1s;
Heating Mold Size: 100X100X70mm;
Test Temperature: 50-500 ºC;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Working Environment Temperature: 0-40 ºC;
Heating Power: 1000W;
Power: Electronic;
Room Temperature: -500 ºC;
Test Circuit Short-Circuit Current: ≤ 50mA;
|
After-sales Service: Yes;
Warranty: 1 Year;
Output Power (Kw): 12;
Double Pressure Weight (Kg): 10+24;
Output Voltage (Kv): 60;
Voltage Measurement Error: 1.0% ± 2 Words;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Double Pressure Cylinder Height (mm): 750;
Chassis Weight (Kg): 35;
Overvoltage Setting Error: ≤ 1%;
Leakage Current Measurement Error: ± 2.0% (Full Scale);
Total Current Measurement Error: 1.0% ± 2 Words;
Output Current (Ma): 200;
Power: Electronic;
|
After-sales Service: Yes;
Warranty: 1 Year;
Output Power (Kw): 12;
Double Pressure Weight (Kg): 10+24;
Output Voltage (Kv): 60;
Voltage Measurement Error: 1.0% ± 2 Words;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Double Pressure Cylinder Height (mm): 750;
Chassis Weight (Kg): 35;
Overvoltage Setting Error: ≤ 1%;
Leakage Current Measurement Error: ± 2.0% (Full Scale);
Total Current Measurement Error: 1.0% ± 2 Words;
Output Current (Ma): 200;
Power: Electronic;
|