| Specification |
After-sales Service: Yes;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: No;
Gaspath System: No;
Detector: UV;
Energy Resolution: N/a;
Spectrometer Detector: UV;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: ID8*25mm;
Chromatographic Column Diameter: ID8*25mm;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: on-Site Training;
Appliance: Dissolved in Oil;
Ray Type: Laser;
Gaspath System: Double;
Detector: PAS;
Energy Resolution: High Accuracy;
Spectrometer Detector: PAS;
Chromatography Type: Photoacoustic Spectroscopy;
Chromatographic Column Type: No Need;
Chromatographic Column Length: No Need;
Chromatographic Column Diameter: No Need;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.1 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
Moisture: 0~100 Ppm;
O2 & N2: Customized;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: on-Site Training;
Appliance: Dissolved in Oil;
Ray Type: Laser;
Gaspath System: Double;
Detector: PAS;
Energy Resolution: High Accuracy;
Spectrometer Detector: PAS;
Chromatography Type: Photoacoustic Spectroscopy;
Chromatographic Column Type: No Need;
Chromatographic Column Length: No Need;
Chromatographic Column Diameter: No Need;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.1 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
Moisture: 0~100 Ppm;
O2 & N2: Customized;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: on-Site Training;
Appliance: Dissolved in Oil;
Ray Type: Laser;
Gaspath System: Double;
Detector: PAS;
Energy Resolution: High Accuracy;
Spectrometer Detector: PAS;
Chromatography Type: Photoacoustic Spectroscopy;
Chromatographic Column Type: No Need;
Chromatographic Column Length: No Need;
Chromatographic Column Diameter: No Need;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.1 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
Moisture: 0~100 Ppm;
O2 & N2: Customized;
|
After-sales Service: 24 Hours' on Line Service;
Warranty: 3 Years;
Appliance: Transformer Oil Dga;
Detector: PAS;
Chromatography Type: Laser PAS;
Test Method: Photoacoustic Spectroscopy;
Light Source: Laser;
Tested Gas: Co, CO2, CH4, C2h2, C2h6, C2h4, H2O and etc.;
H2: 2 Ppm;
CO2: 25 Ppm;
Co: 25 Ppm;
CH4: 0.5 Ppm;
C2h2: 0.05 Ppm;
C2h4: 0.5 Ppm;
C2h6: 0.5 Ppm;
|